"Roh-roh Raggy we rav rah roblem." Scooby does not like this at all, and he's right... Follow the orange line and try to figure out where we've made a mistake?
#1 The regulator is sensing voltage at the HOUSE bank and waiting to see a change.
#2 The alternator is feeding directly to the START battery but the voltage being sensed by the regulator is not budging, on the house bank, and why would it?
#3 In this scenario the regulator remains in FULL FIELD (full output mode) driving the voltage of bank 2 through the roof! We have an alternator being told to stay in bulk charging and a START battery that was nearly full to begin with. The result is the bank 2 voltage rising uncontrolled and frying the battery...
I have seen far too many batteries destroyed by this blunder over the years and the manuals apparently do not make this clear enough, for all installers.
© All Images property of Compass Marine Inc.
Mark Hayward | 08-Jun-2015 00:39 | |