This one is a beauty.... The double pole AC inlet breaker is meant to interrupt the WHITE/NEUTRAL AC feed and BLACK/HOT AC feed wires. This installer took it upon himself to omit breaking the WHITE/NEUTRAL and simply jumped out the BLACK HOT.... AC wiring can be deadly! Major FAIL......
© All Images property of Compass Marine Inc.