photo sharing and upload picture albums photo forums search pictures popular photos photography help login
Compass Marine How To | all galleries >> Compass Marine How To Articles >> Understanding the Moisture Meter / Electrophysics CT-33 > Meter Reading of Dry Test Panel
previous | next
Meter Reading of Dry Test Panel
29-OCT-2008

Meter Reading of Dry Test Panel

Now I know what you're probably thinking "it's already wet"? If you thought that you'd be wrong. This 6% reading is actually about as bone dry as you'll ever get on either solid or cored fiberglass using the CT-33. Using this meter any reading between 0% & 15% is considered dry on fiberglass.


Remember this meter is primarily designed for the many different species of wood. It may also be used on man made materials such as fiberglass. You'll need to reference the scale found at the end of this page for fiberglass interpretations/translations.


Contrary to popular belief moisture meters don't actually read moisture. They actually read capacitance. This capacitance reading is then transposed, onto the analog display, into a relative moisture reading.

Nikon D200
1/60s f/4.0 at 48.0mm iso100 hide exif
Full EXIF Info
Date/Time29-Oct-2008 12:39:44
MakeNikon
ModelNIKON D200
Flash UsedNo
Focal Length48 mm
Exposure Time1/60 sec
Aperturef/4
ISO Equivalent100
Exposure Bias
White Balance
Metering Modematrix (5)
JPEG Quality
Exposure Programprogram (2)
Focus Distance

other sizes: small medium large